XK3190-NA2S Weighing indicator adopts fast speed, high precision ∑-Δ A/D conversion technology and special anti-vibration software technology, widely applied in electronic platform scale、electronic floor scale、mechanic-electronic conversion scale and so on alike static weighing system equipped with 1~4 load cell. 

Keywords:

XK3190-NA2S Weighing indicator adopts fast speed, high precision ∑-Δ A/D conversion technology and special anti-vibration software technology, widely applied in electronic platform scale、electronic floor scale、mechanic-electronic conversion scale and so on alike static weighing system equipped with 1~4 load cell. 

Standard Function

 ◆High precision A/D conversion with readability 1/30000

◆Call and display inner code to replace weight observing and analysis tolerance

◆Special digital filtering technology to strengthen anti-vibration ability

◆Able to set up digital filter intensity、range and stable time

◆With counting function (unit weight data save protection in case of power off)

◆Selectable backlight mode

◆Alarm for low battery and auto power off at low battery, with built-in rechargeable 6V/4AH battery

◆Enhanced EMC design effectively eliminates EMR disturbance of power supply and outside

◆Fourfold cheat-proof by both software and hardware

◆Good electric safety performance

◆Double power supply design to ensure independence and stability of A/D conversion

Technical Parameter

◆Accuracy class: III

◆Max verified counts: nind=6000

◆A/D conversion method: ∑-Δ

◆A/D conversion speed: 10 times/sec.

◆Max. A/D conversion bits: 20

◆Input signal range: -10mV~15mV

◆Load cell excitation: DC 5V; I≤150mA

◆Max. connection number of load cell: 4 at 350 ohm

◆Load cell connection mode: 6 wire

◆Max. external counts: 30000

◆Max. internal resolution: 300000

◆Division: 1/2/5/10/20/50 optional

◆Display: 6 digits LED, 6 status indications

◆Display range: -2000~150000(d=10)

◆Power supply: AC 187~242V,49~51Hz; DC built-in rechargeable 6V/4AH battery

Optional

Scoreboard interface

◆Signal output method:current loop signal

◆Baud rate:600,transmission distance: Current loop≤2000 meters

Serial communication interface

◆Standard configuration:RS232C,baud rate seletable:1200/2400/4800/9600

◆Communication method:continuous sending method

◆Transmission distance: RS232C≤30 meters